Subscription journal ISSN (Print) 1098-4321 - ISSN (Online) 1557-2196 This journal is no longer being updated because: RSS feed has been removed by publisher
Please help us test our new pre-print finding feature by giving the pre-print link a rating. A 5 star rating indicates the linked pre-print has the exact same content as the published article.
Authors:Ashtekar D. Pages: 1 - 17 Abstract: AbstractCurrently, limited guidance is available for the contamination control of visible particles for the manufacture of sterile devices; thus, a comprehensive guidance is warranted. Sterile devices require stringent control of visible particulates to ensure proper functionality, performance assurance of sterility, reliability, patient safety, efficacy, and product quality. This paper outlines practical and science-based strategies to prevent/minimize visible particle contamination from non-process related extrinsic and process related intrinsic sources. Witness plates are proposed as a comprehensive strategy for the real time detection of visible particles, sources of extrinsic and intrinsic visible particles, and methods to identify particle types. Implementing the control measures described herein, which include air ionization units for the control and neutralization of static charges, would maximize device yield and quality, thus reducing rework and leading to increased profitability. Installing validated air ionization systems at appropriate manufacturing and processing locations, storage, product transfer areas, and gown-up rooms can significantly reduce visible particle contamination accumulation, dispersion, and yield losses. Implementing effective material transfer practices can further minimize the risk of introduction of unwanted particles and particle dispersion within classified areas. Also described are additional control measures, such as material systems and supply chain controls, good facility design, gowning practices, manufacturing equipment and tool controls, and manual visual inspections which would further contribute to the overall reduction of particle burden. Crucial elements of an effective particle removal process are the dry and wet cleaning processes and the facility surveillance program. Process-product-particle traceability matrices can serve as effective tools to promptly identify trends and reduce device conformity defects. For this paper, the meaning of the term particle only includes particulates and particulate matter. Microbial contamination control approaches, including facility decontamination, are outside the scope of this paper. PubDate: Wed, 22 Dec 2021 00:00:00 GMT DOI: 10.17764/1557-2196-64.1.1 Issue No:Vol. 64, No. 1 (2021)
Please help us test our new pre-print finding feature by giving the pre-print link a rating. A 5 star rating indicates the linked pre-print has the exact same content as the published article.
Authors:Dawson T; Rutherford G, Hill C, et al. Pages: 18 - 29 Abstract: AbstractThe SAGE III Contamination Monitoring Package detects the contamination environment in the immediate vicinity of the payload using eight Thermoelectric Quartz Crystal Microbalance sensors that telemeter continuous beat frequency measurements to the ground. The single greatest source of contamination measured to date was the SpaceX Cargo Dragon, whose outgassed contaminants chemisorbed to the gold electrodes of the sensors. This paper contains results from the mission’s first three years, including the signals observed from every visible visiting vehicle, the measured effects on the overall payload, and learned lessons to consider for future ISS or TQCM missions. PubDate: Wed, 22 Dec 2021 00:00:00 GMT DOI: 10.17764/1557-2196-64.1.18 Issue No:Vol. 64, No. 1 (2021)
Please help us test our new pre-print finding feature by giving the pre-print link a rating. A 5 star rating indicates the linked pre-print has the exact same content as the published article.
Authors:Cerimele M; Homan J, Garcia S, et al. Pages: 30 - 41 Abstract: AbstractNASA is the mission lead for the James Webb Space Telescope (JWST), the next of the “Great Observatories,” scheduled for launch in 2021. NASA is directly responsible for the integration and test (I&T) program that culminated in an end-to-end cryo vacuum optical test of the flight telescope and instrument module in Chamber A at NASA Johnson Space Center. Historic Chamber A is the largest thermal vacuum chamber at Johnson Space Center and one of the largest space simulation chambers in the world. Chamber A has undergone a major modernization effort to support the deep cryogenic, vacuum and cleanliness requirements for testing the JWST. This paper describes the upgrades to the Chamber A facility: Thermal Shrouds, Helium Refrigeration, Liquid Nitrogen System, High Vacuum System, Clean Airflow System, and Utilities. PubDate: Wed, 22 Dec 2021 00:00:00 GMT DOI: 10.17764/1557-2196-64.1.30 Issue No:Vol. 64, No. 1 (2021)
Please help us test our new pre-print finding feature by giving the pre-print link a rating. A 5 star rating indicates the linked pre-print has the exact same content as the published article.
Authors:Taylor C; Notohardjono B, Khambati S, et al. Pages: 42 - 49 Abstract: AbstractIn optimizing packaging design, the product’s fragility is qualified by a protype undergoing quantitative and qualitative tests that rely heavily on past knowledge and experiments. By the addition of finite element analysis (FEA), the product’s fragility can be obtained in the initial stages of product design with material characterization and simulation. FEA can predict Gs on the product as well as examine the strains, which interpret product failure more easily in the design stage. To incorporate FEA, first the foam material was measured at various strain rates under compression. Next a shipping package containing an Al block with consistent density was dropped at different heights—610 mm (24”), 915 mm (36”), and 1067 mm (42”)—to confirm the methodology. An I/O book was packaged for the final demonstration incorporating FEA with an electronic card package. In an electronic card package, the electronic assemblies are sensitive to strains on the system board. If the strains on the board are high, the assemblies’ solder connections to the board could be damaged and result in a defect during shipment. The simulations’ predicted Gs and board strains were compared to experimental drop testing results at 610 mm (24”) and 915 mm (36”). The simulation results for each sensor location were within reasonable approximation of the experimental results, verifying that FEA could be used in the initial design stages to predict the accelerations and strains for packaging development in parallel to the product design. PubDate: Wed, 22 Dec 2021 00:00:00 GMT DOI: 10.17764/1557-2196-64.1.42 Issue No:Vol. 64, No. 1 (2021)
Please help us test our new pre-print finding feature by giving the pre-print link a rating. A 5 star rating indicates the linked pre-print has the exact same content as the published article.
Authors:White GO. Pages: 50 - 56 Abstract: AbstractThis paper introduces and develops the Velocity Intensity Spectrum as an analytical tool for examining transient data in the frequency domain. The Velocity Intensity Spectrum is then compared with three common alternatives: the Shock Response Spectrum, the Pseudo Velocity Spectrum, and the lesser-known Shock Intensity Spectrum, upon which it is based. The various techniques are applied to an experimental data set and compared and discussed in a practical manner. PubDate: Wed, 22 Dec 2021 00:00:00 GMT DOI: 10.17764/1557-2196-64.1.50 Issue No:Vol. 64, No. 1 (2021)
Please help us test our new pre-print finding feature by giving the pre-print link a rating. A 5 star rating indicates the linked pre-print has the exact same content as the published article.
Authors:Ensor DS; Mielke R, Sklena J. Pages: 57 - 67 Abstract: AbstractInternational Organization for Standardization (ISO) Technical Committee (TC) 209’s first meeting was held in November 1993.The focus was on cleanrooms and controlled environments and the activities within cleanrooms. The TC has moved in recent years to generic operations documents such as a systematic approach for procuring disposables and particle deposition rate monitoring to improve the quality of products manufactured in a cleanroom. ISO stresses development of standards with requirements to support sustainability. A recently published standard on energy management in a cleanroom supports that need. ISO has a range of publication formats with different rigor in balloting to reduce document development being considered by the TC. ISO/TC 209 begins its third decade taking a more integrated approach to standardization with the goal of responding to the needs of industry. PubDate: Wed, 22 Dec 2021 00:00:00 GMT DOI: 10.17764/1557-2196-64.1.57 Issue No:Vol. 64, No. 1 (2021)